Nzs 3604 Roof Framing

Constructing Timber Outriggers Branz Build

Constructing Timber Outriggers Branz Build

Branz Now Recommend Using 10 Mm Of Xps As A Thermal Break For Slab Edge Insulation Concrete Slab Broken Concrete Insulation

Branz Now Recommend Using 10 Mm Of Xps As A Thermal Break For Slab Edge Insulation Concrete Slab Broken Concrete Insulation

Magroc Insulfound Magroc Building Insulation Exterior Cladding Building Systems

Magroc Insulfound Magroc Building Insulation Exterior Cladding Building Systems

Timber Framed Buildings

Timber Framed Buildings

Securing Buildings Against Uplift Branz Build

Securing Buildings Against Uplift Branz Build

Figure 1 Reinforcing For In Situ Concrete Foundation Wall For Single Storey Building Foundation Concrete Foundation

Figure 1 Reinforcing For In Situ Concrete Foundation Wall For Single Storey Building Foundation Concrete Foundation

Figure 1 Reinforcing For In Situ Concrete Foundation Wall For Single Storey Building Foundation Concrete Foundation

Current the latest up to date edition.

Nzs 3604 roof framing.

You can follow nzs 3604 for structure and e2 as1 for the roof and wall claddings. Lightweight roof claddings generally for residential structures built according to nzs 3604 2011 timber framed buildings a lightweight roof cladding is considered to have a mass no greater than 20 kg m. 1 and 2 new zealand standard timber framed buildings superseding nzs 3604 1990 and nzmp 3600 part 1 1992. 10 roof framing 11 building envelope roof and wall claddings 12 interior linings 13 ceilings additional information normative.

Nzs 3604 1999 incorporating amendment no. Nzs 3604 sets down construction requirements for timber framed buildings within the limitations specified in 1 1 2 nzs 3604 applies only to buildings within the following limitations this is not a complete list. Builders architects engineers designers and students will find it useful. This modern profile metal sheet roofing is an example of a lightweight roof cladding.

Simply stated it requires that bracing for monopitch roofs must comply with paragraphs 10 3 2 for light roofs or 10 3 3 for heavy roofs but it also includes an exemption. It is aligned with as nzs 1170 structural design actions and is referenced in acceptable solution for building code clause e2 external moisture e2 as1. The rafter span is 3 000 m and because this is a light roof the far right column of nzs 3604 2011 table 10 1 rafters for all wind zones see figure 2 can be used for rafter spacings at 1200 mm see note 4 in table 10 1. Nzs 3604 is used to design most homes and other low rise timber framed buildings in new zealand.

A buildings shall be founded on good ground. It provides methods and details that are used to design many nz timber framed houses and small buildings including many residential decks. In the previous version of nzs 3604 purlin tables provided for extra fixings around roof edges and ridges reflecting the greater wind uplift in these areas. B buildings shall be category iv or v buildings see table 1 1.

Nzs 3604 is new zealand s most sought after standard. The bracing requirementfor monopitch roofs is addressed in nzs 3604 2011 timber framed buildingsparagraph 10 3 4.

As1684 Residential Timber Framed Construction Bracing Example Timber Frame Construction Floor Framing Concrete Footings

As1684 Residential Timber Framed Construction Bracing Example Timber Frame Construction Floor Framing Concrete Footings

Roof Form And Framing Original Details Branz Renovate

Roof Form And Framing Original Details Branz Renovate

Figure 2 Reinforcing For Cantilevered Foundation Wall For 1 Or 2 Storeys Note Horizontal Reinforcing In Bond Beam 800 Building Foundation Wall Foundation

Figure 2 Reinforcing For Cantilevered Foundation Wall For 1 Or 2 Storeys Note Horizontal Reinforcing In Bond Beam 800 Building Foundation Wall Foundation

Veranda Rafter Fixings Branz Build

Veranda Rafter Fixings Branz Build

Source : pinterest.com